Figure 2: Voice band insertion loss 18 kft cable vs 18 kft cable with load coils after 6 kft and 12 kft
Load Coil 88mH
Model: SA-2642-8801
Categories
The CNI Load Coil is placed along a telephone line to compensate for the losses in signal over long distances. The load coil induces an electrical current via magnetic fields to compensate for lost signal power.
The SA-2642-8801 load coil has a Loop inductance of 88mH and is designed to moderate the loss in signals, or attenuation, or minimize it at high voice frequencies in telephone lines. They are recommended for loops larger than 18Kft and the 88mh coil will cancel 6,000ft of capacitance, therefore they are to be placed in 6Kft intervals to lower the electrical losses at high frequencies.
Specifications
Wiring
IN Pin 1: Blue Wire
Pin 4: Blue/White Wire
OUT Pin 2: Orange Wire
Pin 3: Orange/White Wire
Loop Inductance
88mH
DC Resistance
4.2 Ω typical